Many Pakenham 3810 homes collect roof water in a rainwater tank for gardens, toilets or laundries, and rural properties nearby may rely on tanks for all household water. The tank is only as good as the gutters, downpipes and pipework that feed it. This page covers how tank connections work, common problems and what to ask a plumber.
How roof water reaches a tank
Water runs from the roof into the gutters, down the downpipes and through pipework to the tank inlet. Along the way it usually passes:
- A leaf diverter or rain head that sheds leaves and larger debris
- A first flush device that diverts the first portion of rain, which carries dust and droppings from the roof
- An inlet strainer or mesh at the tank to keep out mosquitoes and debris
From the tank, an overflow pipe carries excess water to the stormwater system or another approved discharge point. If the tank supplies the house, a pump and possibly a mains water switching device are connected as well.
Wet and dry systems
The pipework between downpipes and tank is either a dry system or a wet system. The choice depends on where the tank is and how many downpipes feed it.
| Feature | Dry system | Wet (charged) system |
|---|---|---|
| Pipe route | Downpipes drop into pipes that run above the tank inlet | Pipes run underground and rise up into the tank |
| Water in pipes after rain | Drains out | Stays in the pipes |
| Typical use | Tank close to the house, near the downpipes | Tank away from the house, several downpipes connected |
| Common issues | Limited by the tank height | Sediment build-up, need for a drain point, possible mosquito breeding if not sealed |
Wet systems need a way to drain sediment, usually a drain valve at the lowest point. Sediment and leaf matter left in the pipes can become smelly and block flow. Ask the plumber where the drain point will be and how often it should be flushed.
Leaf diverters and first flush devices
Leaf diverters sit on the downpipe or replace a section of it, with a mesh screen at an angle so leaves slide off while water passes through. They need cleaning, especially in autumn and near eucalypts.
First flush devices hold the first part of each rainfall in a chamber, then let cleaner water pass to the tank. The chamber drains slowly through a small outlet. If the outlet blocks, the device stays full and no longer works. Check and clean first flush devices regularly. Their capacity should suit the roof area feeding them.
Gutter guards can reduce the debris reaching these devices, but they do not replace them. The gutter guards page explains guard options.
Tank overflow and stormwater
When the tank is full, extra water leaves through the overflow pipe. The overflow must go somewhere approved, usually the property’s stormwater system, which then flows to the legal point of discharge. Letting the overflow run onto the ground next to the house or tank can soak foundations, erode soil and flood neighbours.
Overflow pipes need a mesh or flap to keep mosquitoes and vermin out, and their size should match the inflow so the tank does not back up into the downpipes. If downpipes overflow during heavy rain when the tank is full, the overflow pipe may be blocked or too small. The guide to downpipes and stormwater explains the stormwater side.
Who does tank plumbing
Running downpipes into a tank, piping its overflow to stormwater and plumbing tank water to toilets or a laundry are all plumbing jobs in Victoria, and larger ones need a licensed or registered plumber plus a compliance certificate. Any link between tank water and the house supply also needs backflow protection fitted by a licensed plumber so tank water cannot reach the mains. Licences can be checked on the Building and Plumbing Commission’s register, and the pump’s power point is a job for a licensed electrician.
Tank placement and base
Tanks are very heavy when full and need a level, stable base, such as a concrete slab, a compacted crushed rock pad or a purpose-built stand. A tank that settles unevenly can split or distort its fittings. Placement also affects how downpipes connect. Tanks near a boundary, easement or building may have rules about setbacks and the effect of overflow. Check the tank manufacturer’s instructions and, if in doubt, ask Cardinia Shire Council or a building surveyor.
Elevated tank stands are structures and need a proper design, especially for larger tanks.
Water quality
Tank water collected from roofs can carry contamination from bird and animal droppings, leaves, dust and roof materials. The Victorian Department of Health publishes guidance on using rainwater tanks safely, including when tank water is suitable for drinking and how to maintain the system. Keeping gutters clean, using leaf diverters and first flush devices, screening inlets and overflows, and desludging the tank periodically all help.
Roofs with lead flashings, old paints, treated timbers or some other materials may not be suitable for collecting drinking water. Ask a plumber or check the Department of Health guidance if you plan to drink tank water.
Bushfire areas
In bushfire prone areas, tanks can be a water source for firefighting. The CFA has guidance on static water supply for firefighting in some situations, including outlet fittings that suit CFA equipment. If your property is in a bushfire area, especially around Pakenham Upper or Nar Nar Goon North, check whether your planning permit or BAL assessment requires a dedicated water supply and fittings. Plastic tanks and pipework above ground can be damaged by fire, so placement and materials matter.
Common tank connection problems
- Downpipes overflowing in heavy rain because the tank inlet or overflow cannot keep up
- Smelly water from sediment in wet system pipes or a tank needing desludging
- Mosquitoes in the tank because screens are missing or damaged
- First flush devices stuck full and no longer diverting water
- Leaf diverters blocked, sending water over the side
- Tank overflow discharging against the house
- Cracked underground pipes losing water before it reaches the tank
What to include in your enquiry
- Tank size, material and location
- Which downpipes feed it, and whether the system is wet or dry if known
- What the water is used for: garden, toilets, laundry or drinking
- Where the tank overflow goes
- Problems you have noticed, such as overflow, smells or low collection
- Photos of the tank, downpipes and connections
Questions for the plumber
- Which downpipes should feed the tank, and what pipework do you recommend?
- Where will the overflow discharge?
- Will you fit leaf diverters, first flush devices and screens?
- Is backflow prevention needed for my connection?
- Will a compliance certificate be issued?
The gutter quote checklist covers general comparison points.
Tanks around Pakenham
Newer homes in Officer and Clyde North often have a tank plumbed to toilets or laundry as part of the original build. Older homes in Pakenham and Beaconsfield may have a garden tank added later. Rural and lifestyle properties toward Nar Nar Goon, Tynong and Pakenham Upper may rely entirely on tanks. The Nar Nar Goon area page has rural notes, and the downpipe repairs page covers downpipe faults that affect tank supply.
Maintenance schedule for tank systems
A simple routine keeps a tank system working:
| Task | How often |
|---|---|
| Clean gutters feeding the tank | Several times a year near trees, at least yearly elsewhere |
| Clean leaf diverter screens | Monthly in autumn, every few months otherwise |
| Check first flush devices drain between rains | Every few months and after long dry spells |
| Check inlet and overflow screens for holes | Every six months |
| Flush wet system drain points | Every few months |
| Check the pump and pressure switch | Yearly, or as the manufacturer recommends |
| Desludge the tank | Every few years, or when sediment builds up |
Keep a note of what you did and when. If water quality changes or the tank fills more slowly than usual, the record helps a plumber find the cause.
Adding a tank to an existing home
If you are adding a tank, plan which roof sections will feed it. The best catchment is a large, clean roof section without overhanging trees, close to the tank site. The downpipes from that section are redirected to the tank, and the tank overflow connects back into the stormwater system. If the tank will supply toilets or a laundry, the plumber also installs a pump, a mains switching device and backflow prevention. A building surveyor or the council can confirm whether a permit is needed for the tank, its base or any stand, particularly for large tanks or tanks near boundaries.
Tank overflow during long wet spells
In a wet Pakenham winter, tanks fill and stay full for weeks, so every rain event sends water through the overflow. A tank overflow that drains slowly, is partly blocked or discharges onto the ground becomes a constant problem in those months. Check the overflow outlet during heavy rain: water should leave freely without backing up into the inlet or downpipes. If the ground near the tank is always soggy in winter, the overflow is probably not connected properly to the stormwater system. Fixing that connection protects the tank base, nearby footings and the neighbours’ land.
Tanks on small estate lots
On smaller lots in Officer and Clyde North, tanks are often slimline units along a side boundary, fed by one or two downpipes. These tanks fill quickly in heavy rain and overflow often, so the overflow connection to stormwater matters. Side paths beside slimline tanks are narrow, which makes access for cleaning and pump servicing awkward. Leave room to reach the leaf diverter, first flush device and pump, and keep the area clear of stored items. If the tank sits on a boundary, check that its overflow and any leaks will not affect the neighbour’s property.
Tank pumps and power
Tank pumps that supply toilets or laundries need a dedicated power point installed by a licensed electrician, protected from the weather. Pump noise can bother neighbours, so place pumps away from bedroom windows on both properties, or use a pump enclosure.
Request help with a tank connection